Maintenance Object Repair Procedure
Inject Single Bit Error Test (#1215)
This test is destructive.
The Inject Single Bit Error test causes a single bit error to be sent within an active
framed 3-in-24 test pattern.
The test is highly destructive and can only be initiated by a system technician
demanded test ds1-loop UUCSS inject-single-bit-error command. An attempt
to use this command will be rejected if none of the three long-duration DS1
loopback/span tests (CPE Loop-Back Jack test, Far CSU Loopback test,
One-Way Span test) are active on a UDS1-BD circuit pack.
Every trunk or port on the UDS1 Interface circuit pack must be busied out using
the system technician busyout board command before running the Inject Single
Bit Error test.
The list measurements ds1 summary command displays the number of bit
errors detected (Loopback/Span Test Bit-Error Count field). Injecting
this single bit error should increment the bit error count of the loopback/span test
by one.
Table 8-541. Test #1215 Inject Single Bit Error Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS inject-single-bit-error command at
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
2. Retry the command.
8-1302
Issue 1 May 2002
1-minute intervals up to 5 times.
the UDS1 Interface circuit pack into the out-of-service state.
Continued on next page