TIE-TRK (Analog Tie Trunk)
Table 8-496. Test #73,#747 Tie Trunk Seizure Test — Continued
Error
Test
Code
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run the test. This could
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
3
FAIL
No dial tone detected from the other end. (TN439 circuit packs only.)
1. Retry the command at one minute intervals up to five times.
2. If the test continues to fail, check the far-end PBX to ensure a translation
3. Check the facility.
2000
FAIL
Seizure message is not received back within 10 seconds.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, check the far-end PBX to ensure a translation
3. Check the facility.
PASS
The Tie Trunk Seizure test passes. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port,
0
NO
The test could not relate the internal ID to the port (no board).
BOARD
1. Verify that the board's translations are correct. Translate the board, if
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
555-233-142
match at both ends.
match at both ends.
wiring, and stations.
necessary.
between the internal ID and the port.
Continued on next page