Avaya S8700 Maintenance Manual page 214

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port's NPE channel talks on the selected
time slot and never crosses over to time slots reserved for other connections. If
the NPE is not working correctly, one-way and noisy connections may be
observed. This test is usually part of a port's long test sequence and takes about
20 to 30 seconds to complete.
Table 8-384. Test #6 NPE Crosstalk Test
Error
Test
Code
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use status pri-endpoint extension commands to
determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to TDM-Bus
errors. Use the status health command to determine whether the system is
experiencing heavy traffic. Investigate and resolve any errors against
TDM-BUS.
1. If the system has no TDM-Bus errors and is not handling heavy traffic,
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some tone detectors may
be out-of-service. The list measurements tone-receiver command will
display information about the system's tone receiver.
1. Resolve any errors against TTR-LEV.
2. Resolve any errors against TONE-PT.
3. If neither of the above exists, retry the test at 1-minute intervals up to 5
1004
ABORT
The port has been seized by a user for a valid call. Use status pri-endpoint
extension to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1117
ABORT
A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
8-910
Issue 1 May 2002
repeat test at 1-minute intervals up to 5 times.
times.
Continued on next page