Avaya S8700 Maintenance Manual page 352

Avaya s8700 media server for ip connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance Object Repair Procedure
Error Log Entries and Test to Clear Values
Table 8-449. Synchronization Maintenance Error Log Entries
Aux
Associated
Error Type
Data
Test
1
0
0
Any
1 (a)*
None
18 (b)
0
disable sync
257 (c)*
None
513 (d)*
None
2
1793 (e)
0–50
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test's description, and follow its recommended procedures.
2.
It may take up to 1 hour for these alarms to clear via the "leaky bucket" strategy.
Notes:
a. This error indicates a problem with the primary DS1 reference. It will be
cleared when the primary reference is restored. The following procedure
should indicate the problem's source:
1. Enter list configuration board UUCSS to check if the primary DS1
2. Verify that the administered primary reference matches the DS1
3. Enter test board UUCSS long to test the primary DS1 Interface
4. Enter test Tone-Clock UUC long to test the active Tone-Clock
8-1048
Issue 1 May 2002
Alarm Level
Any
WARNING/MINOR (f)
WARNING
WARNING/MINOR (f)
WARNING/MAJOR (f)
MAJOR
Interface circuit pack is inserted in the carrier.
reference from the network synchronization plan.
circuit pack.
Check the Error Log for DS1-BD or UDS1-BD errors and see
''DS1-BD (DS1 Interface Circuit Pack)''
Interface Circuit Pack)''
primary DS1 (DS1 or UDS1) interface circuit pack.
If the only errors against DS1-BD or UDS1-BD are slip errors, then
follow the procedures described in the previous troubleshooting
section. If no errors are listed in the Error Log for the primary DS1
Interface circuit pack, continue with the following steps.
circuit pack in the master port network.
Check the Error Log for TDM-CLK errors, and verify that TDM Bus
Clock Circuit Status Inquiry test (#148), passes.
If Test #148 fails with Error Code 2–32, see
Clock)''
to resolve the problem. If not, continue with the following
steps.
On/Off
Board
Test to Clear Value
Any
test synchronization
OFF
None
OFF
enable sync
OFF
None
OFF
None
OFF
None
or
''UDS1-BD (UDS1
to resolve any errors associated with the
''TDM-CLK (TDM Bus
555-233-142