XXX-BD (Common Port Circuit Pack)
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has been
physically removed from the system. This error type does not apply to
ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is
logged approximately 11 minutes after removal of the circuit pack or failure
of the SAKI Sanity test (#53).
Check for the physical presence of the circuit pack in the slot indicated by
the alarm. If the circuit pack is absent, insert one of the proper type. If the
circuit pack is present and its red LED is lit, see
Log Entry or with Error Type 1'' on page
b. This error indicates the circuit pack has been busied out. Release the
circuit pack via release board UUCSS.
c. The circuit pack has been logically administered but not physically
installed. The alarm should clear when the circuit pact is installed.
If the circuit pack is already installed:
1. Run test board UUCSS long and look at any test failures or error
2. If the test does not clear error 23, then execute reset board UUCSS
3. If the reset/test does not clear error 23, replace the circuit pack.
d. This error applies only to the Maintenance/Test circuit pack (TN771B or
TN771C). The error indicates that the hardware associated with the
Analog Trunk Testing port of the circuit pack failed to initialize. Note that
when this error occurs, the Maintenance/Test circuit pack may report an
invalid vintage. Although this error is not service-affecting, the
Maintenance/Test circuit pack should be replaced.
e. The circuit pack physically installed in the slot does not match the type that
is administered for that slot. Do one of the following:
f. This error applies to the Maintenance/Test circuit pack TN771D), Tone
Detector (TN748B, TN748C, or TN748D), and Call Classifier (TN748)
circuit packs. For the Maintenance/Test circuit pack, the error indicates
that there is more than one Maintenance/Test circuit pack in the port
network. For the Tone Detector or Call Classifier packs, the error indicates
that there are more than 10 circuit packs in the system. Remove the circuit
pack against which the error is logged.
g. This error indicates transient communication problems with this circuit
pack. This error is not service-affecting and no action is required.
555-233-142
codes generated.
and run the long test again.
Remove the incorrect circuit pack and replace it with one of the type
that is administered for that slot.
Use change circuit pack to readminister the slot so that it matches
the board that is installed, and follow with reset board.
''LED Alarms without Alarm