PPP-PT (Control LAN Packet/Port)
Table 8-411. Test #1279 PPP Link Status Inquiry Test — Continued
Error
Test
Code
Result
Description / Recommendation
FAIL
PPP link is down.
1. Test the port (test port UUCSSpp long) to verify the SCOTCH
2. If the test passes, wait for sessions to come up.
3. If the test fails, check the destination and other components in the path
4. If the destination and other components in the path are in-service and the
5. If the test still fails, reset the circuit pack (busyout board UUCSS, reset
6. If the problem persists, replace the circuit pack.
PASS
PPP link is up.
555-233-142
Synchronous Local Loop Around test (#1275) result.
(e.g., DS1 trunks).
test still fails, execute busyout port UUCSSpp and release port
UCCSSpp, and repeat the test.
board UUCSS, and release board UUCSS). Repeat the test.