PDATA-PT (Packet Data Line Port)
Table 8-374. Test #603 System Port Connectivity Test — Continued
Error
Test
Code
Result
Description / Recommendation
1115
ABORT
The PDATA port resources could not be allocated.
1. Run the busyout port UUCSSpp
2. Run the test again
3. Retry the command at 1-minute intervals up to 3 times.
4. Release the port when done.
2012
ABORT
System Call Failed
2031
ABORT
Uplink messages software failed.
2500
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
7
FAIL
Wiring does not match administration.
8
FAIL
Invalid test message sequence.
10
FAIL
Data Line port did not reset correctly.
11
FAIL
PDATA port Data Terminal Ready (DTR) did not reset correctly.
12
FAIL
PDATA port did not reset correctly.
2000
FAIL
Test timed out, most probably the administered ports are not connected
correctly. For the above failure codes, use the following steps to correct the
problem.
1. Enter the commands list data-module and status data-module
2. Retry test up to 2 times, no need to wait between tests.
3. If the test still fails, and the other ports on the circuit pack are idle, enter
4. Retry test up to 2 times.
5. Replace the PDATA board.
6. Retry test up to 2 times.
7. Replace the Data Line circuit pack.
8. Retry test up to 2 times.
PASS
The PDATA port and the Data Line port of the System Port feature are wired
together as administered.
555-233-142
extension on the G3-MT to find the corresponding Data Line port number
and PDATA port number. Check the wiring between the PDATA port and
the Data Line port. Look for loose connections, mis-wiring or broken wires.
reset board UUCSS. (Use status data-module extension or LED
indicators to determine whether other ports are idle).
Continued on next page