Troubleshooting the TX Matrix Plus Host Subsystem

Problem
Solution

Troubleshooting the TX Matrix Plus TXP-CBs

Problem
Solution
Copyright © 2010, Juniper Networks, Inc.
During normal operation, the blue
the host subsystem is functional.
The following indicate a problem with the host subsystem:
The
LED on the TXP-CB is off.
OK
The
FAIL
LED on the TXP-CB is lit green when the host subsystem detects a fault.
An alarm indicates that a host subsystem has been removed or failed.
The text in the column labeled "LCD Message" appears in the display of the craft interface.
The text in the column labeled "CLI Message" appears in the output from the
command.
show chassis alarms

Table 53: TX Matrix Plus Chassis Host Subsystem Alarm Messages

Component
Alarm Type
Host subsystems
Red
Yellow
During normal operation, the blue
the TXP-CB is functional.
The following indicate a problem with the TXP-CB:
The
OK
LED on the TXP-CB is off.
The
LED on the TXP-CB is lit green when the host subsystem detects a fault.
FAIL
An alarm indicates that a TXP-CB has been removed or failed.
user@host> show chassis environment cb sfc 0
sfc0-re0:
--------------------------------------------------------------------------
CB 0 status:
State
Temperature
Power 1
1.0 V
1.1 V
1.2 V
1.25 V
1.5 V
1.8 V
2.5 V
Chapter 21: Troubleshooting TX Matrix Plus Hardware Components
LED on each TXP-CB is on steadily, indicating that
OK
Craft Interface
Message
Host host-number
Removed
Host host-number Failure
OK
LED on each TXP-CB is on steadily, indicating that
Online Master
38 degrees C / 100 degrees F
1005 mV
1108 mV
1205 mV
1269 mV
1508 mV
1814 mV
2507 mV
CLI Message
Host host-number Removed
Host host-number Failure
311