Copyright © 2010, Juniper Networks, Inc.
Carefully slide the TXP-F13 SIB all the way into the card cage until you feel resistance.
6.
Simultaneously turn both left and right ejector handles clockwise to seat the TXP-F13
7.
SIB.
Remove the dust cover from covering each TXP-F13 SIB fiber-optic array port.
8.
Remove the dust covers from the fiber-optic array cable connectors.
9.
Clean the fiber-optic array ports and cables.
10.
CAUTION: While you replace a fiber-optic array cable, small deposits of
oil, dust, and debris can enter the TXP-F13 SIB and TXP-T1600 SIB
fiber-optic array ports, the fiber-optic array cables. We recommend that
you clean the optics in these components, as well as the dust covers,
immediately before connecting them.
Connect each cable (up to eight) to its corresponding TXP-F13 SIB port. Align the
11.
cable with its corresponding TXP-F13 SIB port and carefully press it into the port until
it stops. The cable and port are keyed to ensure proper mating.
NOTE: The optics in a fiber-optic array port are spring loaded, so you must
continue to apply force to a fiber-optic array cable or loopback connector
while securing it to a TXP-F13 SIB.
Use one of the following methods to bring the TXP-F13 SIB online:
12.
Press and hold the
SIB ONLINE/OFFLINE
faceplate. The green
SIB is installed.
Issue the following CLI command:
user@host> request chassis sib f13 slot slot-number online
Verify that the TXP-F13 SIB is functioning normally:
13.
Verify that the green
Verify that the TXP-F13 SIB is online by issuing the
Chapter 22: Replacing TX Matrix Plus Hardware Components
button in the middle of the TXP-F13 SIB
LED should light steadily a few minutes after the TXP-F13
OK
LED is lit steadily.
OK
show chassis sibs
command.