COPIER> ADJUST> CCD
MTF2-M6
MTF value setting 6: main scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M7
MTF value setting 7: main scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M8
MTF value setting 8: main scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-M9
MTF value setting 9: main scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S1
MTF value setting 1: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
COPIER> ADJUST> CCD
MTF2-S2
MTF value setting 2: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S3
MTF value setting 3: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S4
MTF value setting 4: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S5
MTF value setting 5: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S6
MTF value setting 6: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8-165
8-165