Canon imagePRESS 1135 Series Service Manual page 1310

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> COUNTER> DRBL-2
PF-FL-SL
Thrgh/fold flappr solend prts countr:PFU
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PF-ST-SL
C-fold stopper solenoid parts countr:PFU
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PF-TR-SL
C-fold tray branch solend prts cuntr:PFU
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PD-PL-R1
Uppr deck pullout rollr prt cuntr:sidePD
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
8
Service Mode > COPIER > COUNTER > DRBL-2
8
Service Mode > COPIER > COUNTER > DRBL-2
COPIER> COUNTER> DRBL-2
PD-BRG-1
Uppr deck sintered brng prt cuntr:sidePD
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PD-PU-R2
Mid deck pickup rollr prts cuntr: sidePD
Lv.1 Details
Middle deck pickup roller(front, rear)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PD-SP-R2
Mid deck seprtn rollr prts cuntr: sidePD
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
PD-FD-R2
Mid deck feed roller prts cunter: sidePD
Lv.1 Details
Middle deck pickup/feed roller
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
8-367
8-367

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents