Canon imagePRESS 1135 Series Service Manual page 1265

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> OPTION> ACCPST-D
ACC7
Set of delivery option connection order
Lv.1 Details
Setting of connecting order for delivery options to be connected with
ARCNET.
Use case
• At the time of installation
• When replacing DC controller PCB/at RAM clear
Adj/set/operate method 1) Check where is ACC 7 option in the connecting order from the
host machine.
2) Enter the order (number), and then press OK key.
3) Turn OFF and then ON the main power of the host machine and
the options.
Display/adj/set range
Type: 8 characters
Node ID: 8 digits
Order: 2 digits
Supplement/memo
Delivery options connected to ARCNET: Stacker, Tandem stacker,
Finisher, Multi-inserter, Perfect binder
ACC8
Set of delivery option connection order
Lv.1 Details
Setting of connecting order for delivery options to be connected with
ARCNET.
Use case
• At the time of installation
• When replacing DC controller PCB/at RAM clear
Adj/set/operate method 1) Check where is ACC 8 option in the connecting order from the
host machine.
2) Enter the order (number), and then press OK key.
3) Turn OFF and then ON the main power of the host machine and
the options.
Display/adj/set range
Type: 8 characters
Node ID: 8 digits
Order: 2 digits
Supplement/memo
Delivery options connected to ARCNET: Stacker, Tandem stacker,
Finisher, Multi-inserter, Perfect binder
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > ACCPST-P
T-8-78
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > ACCPST-P
■ ACCPST-P
COPIER> OPTION> ACCPST-P
ACC1
Set of pickup option connection order
Lv.1 Details
Setting of connecting order for pickup options to be connected with
ARCNET.
Use case
• At the time of installation
• When replacing DC controller PCB/at RAM clear
Adj/set/operate method 1) Check where is ACC 1 option in the connecting order from the
host machine.
2) Enter the order (number), and then press OK key.
3) Turn OFF and then ON the main power of the host machine and
the options.
Display/adj/set range
Type: 8 characters
Node ID: 8 digits
Order: 2 digits
Supplement/memo
Pickup options to be connected with ARCNET: POD deck, secondary
POD deck
ACC2
Set of pickup option connection order
Lv.1 Details
Setting of connecting order for pickup options to be connected with
ARCNET.
Use case
• At the time of installation
• When replacing DC controller PCB/at RAM clear
Adj/set/operate method 1) Check where is ACC 2 option in the connecting order from the
host machine.
2) Enter the order (number), and then press OK key.
3) Turn OFF and then ON the main power of the host machine and
the options.
Display/adj/set range
Type: 8 characters
Node ID: 8 digits
Order: 2 digits
Supplement/memo
Pickup options to be connected with ARCNET: POD deck, secondary
POD deck
ACC3
Set of pickup option connection order
Lv.1 Details
Setting of connecting order for pickup options to be connected with
ARCNET.
Use case
• At the time of installation
• When replacing DC controller PCB/at RAM clear
Adj/set/operate method 1) Check where is ACC 3 option in the connecting order from the
host machine.
2) Enter the order (number), and then press OK key.
3) Turn OFF and then ON the main power of the host machine and
the options.
Display/adj/set range
Type: 8 characters
Node ID: 8 digits
Order: 2 digits
Supplement/memo
Pickup options to be connected with ARCNET: POD deck, secondary
POD deck
8-322