Canon imagePRESS 1135 Series Service Manual page 1032

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

Address
bit
Name
P278
15
Middle deck paper indicator LED8 ON
14
Middle deck paper indicator LED7 ON
13
Middle deck paper indicator LED6 ON
12
Middle deck paper indicator LED5 ON
11
Middle deck paper indicator LED4 ON
10
Middle deck paper indicator LED3 ON
9
Middle deck paper indicator LED2 ON
8
Middle deck paper indicator LED1 ON
7
Middle deck side right fan_CONT0
6
Middle deck side left fan_CONT0
5
Middle deck lifter motor CCW
4
Middle deck lifter motor CW
3
Middle deck open/close solenoid ON
2
Middle deck open/close LED ON
1
Middle deck paper supply indicator LED
ON
0
Middle deck operating indicator LED ON
P279
15
Middle deck trail edge paper surface
sensor (rear)
14
Middle deck floatation air heater High
temperature Detection
13
Middle deck floatation air heater Low
temperature Detection
12
Middle deck trail edge paper surface
sensor (front)
11
Not use
10
Not use
9
Middle deck suction fan ON
8
Middle deck side left fan_CONT1
7
Middle deck middle paper surface sensor
6
Middle deck suction completion sensor
5
Middle deck paper sensor
4
Middle deck pull-out sensor
3
Middle deck lifter upper limit sensor
2
Middle deck foreign substance sensor
1
Middle deck lead edge upper limit paper
surface sensor
0
Middle deck lead edge lower limit paper
surface sensor
8
Service Mode > COPIER > I / O > Multi Drawer Document Insertion (SORTER > P261 to P304)
Symbol
Remarks
LED8
0: OFF, 1: ON
LED7
0: OFF, 1: ON
LED6
0: OFF, 1: ON
LED5
0: OFF, 1: ON
LED4
0: OFF, 1: ON
LED3
0: OFF, 1: ON
LED2
0: OFF, 1: ON
LED1
0: OFF, 1: ON
FM708
-
FM707
-
M703
-
M703
-
SL703
0: Open, 1: Close
-
0: OFF, 1: ON
-
0: OFF, 1: ON
-
0: OFF, 1: ON
PS716
0: No paper, 1: Paper
-
0: Normal, 1: High
temperature
-
0: Low temperature, 1:
Normal
PS715
0: No paper, 1: Paper
-
-
-
-
FM701
0: OFF, 1: ON
FM708
-
PS705
0: No paper, 1: Paper
PS706
0: Complete, 1: Not
complete
PS702
0: No paper, 1: Paper
PS701
0: No paper, 1: Paper
PS714
0: Normal /
1: upper limit
PS713
1: foreign / substance
exist
PS704
0: No paper, 1: Paper
PS703
0: No paper, 1: Paper
8
Service Mode > COPIER > I / O > Multi Drawer Document Insertion (SORTER > P261 to P304)
Address
bit
Name
P280
15
Middle deck J2102 connect sensor
14
Middle deck lifter lower limit switch
13
Middle deck lifter lower position sensor
12
Middle deck supply position sensor
11
Middle deck J2150 connect sensor
10
Middle deck suction fan error
9
Middle deck pickup driver PCB 24V error
sensor
8
Middle deck open/close sensor
7
Middle deck indicator driver PCB 12V
error sensor
6
Middle deck driver PCB 5V error sensor
5
Middle deck driver PCB 12V error sensor
4
Middle deck driver PCB 24V error sensor
3
Middle deck J2101 connect sensor
2
Middle deck interlock switch
1
Middle deck side right fan
0
Middle deck side left fan
P281
15
Power supply cooling fan 1-ON
14
Path driver cooling fan ON
13
Double feeding detection PCB power
supply ON
12
Power supply cooling fan 2 ON
11
Delivery tray full detection light emission
PCB Input
10
-
9
-
8
-
7
Lower vertical path motor 2-I1
6
Lower vertical path motor 2-I0
5
Lower vertical path motor 2-2PHASE
4
Lower vertical path motor 2-CLK
3
Lower vertical path motor 1-I1
2
Lower vertical path motor 1-I0
1
Lower vertical path motor 1-2PHASE
0
Lower vertical path motor 1CLK
8-89
Symbol
Remarks
PCB703
0: Not connected,
1: Connected
MS702
0: Normal, 1: Lower limit
PS712
0: Lower position,
1: Others
PS709
0: Supply position,
1: Others
PCB703
0: Not connected,
1: Connected
FM701
0: Error, 1: Normal
PCB701
0: Normal, 1: Error
PS707
0: Open, 1: Close
PCB704
0: Normal, 1: Error
PCB703
0: Normal, 1: Error
PCB703
0: Normal, 1: Error
PCB703
0: Normal, 1: Error
PCB703
0: Not connected,
1: Connected
MS703
0: Open, 1: Close
FM708
0: Error, 1: Rotaiton
FM707
0: Error, 1: Rotaiton
FM2
0: OFF, 1: ON
FM1
0: OFF, 1: ON
PCB6/
0: OFF, 1: ON
PCB7
FM3
0: OFF, 1: ON
-
0: Left sensor, 1: Right
sensor
-
-
-
-
-
-
M13
-
M13
-
M13
0: 2 phase, 1: 1-2 phase
M13
1: Counted
M12
-
M12
-
M12
0: 2 phase, 1: 1-2 phase
M12
1: Counted
8-89

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents