COPIER > OPTION > USER
COPY-LIM
Setting of upper limit for copy
Lv.1 Details
Setting the upper limit value for copy.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key
2) Turn OFF and then ON the main power supply.
Display/adj/set range
1 to 9999
Default value
9999
SLEEP
Setting of auto sleep function
Lv.1 Details
ON/OFF setting for auto sleep function.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
Supplement/memo
Specify the time for shifting to sleep mode in User Mode (Timer
Settings> Auto Sleep Time)
SIZE-DET
ON/OFF of original size detect function
Lv.2 Details
ON/OFF setting for original size detection function.
Use case
Upon request from the user (glare of the document lamp, etc)
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
1
COUNTER1
Display of software counter 1
Lv.1 Details
Displaying counter type for software counter 1 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Caution
Display only. No change is available.
Default value
The value differs according to the location.
COUNTER2
Display of software counter 2
Lv.1 Details
Displaying counter type for software counter 2 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 999
Default value
The value differs according to the location.
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
COPIER > OPTION > USER
COUNTER3
Display of software counter 3
Lv.1 Details
Displaying counter type for software counter 3 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 999
Default value
The value differs according to the location.
COUNTER4
Display of software counter 4
Lv.1 Details
Displaying counter type for software counter 4 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 999
Default value
The value differs according to the location.
COUNTER5
Display of software counter 5
Lv.1 Details
Displaying counter type for software counter 5 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 999
Default value
0
COUNTER6
Display of software counter 6
Lv.1 Details
Displaying counter type for software counter 6 on the screen to
check counter status
Use case
Upon request from the user/ dealer
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 999
Default value
0
DATE-DSP
Setting of data/time display format
Lv.2 Details
Setting date/time display style according to the country or region.
The order to display date, which is specified by going through the
following: System Settings> Date/Time Settings; followed by the
order to be printed in the report.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 2
0: YYMM/DD, 1: DD/MMYY, 2: MM/DD/YY
Default value
The value differs according to the location.