Canon imagePRESS 1135 Series Service Manual page 1322

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> COUNTER> CLEANING
FD-U-2
Feed assembly cleaning counter (500K)
Lv.1 Details
Display the number of sheets transported by the feed assembly and
timing of cleaning as a guide.
Counter on the 1st line shows the number of sheets transported after
the previous cleaning.
Enter the cleaning timing value into the 2nd line as a guide for
operators. This is linked to AVE-CLN> FD-U-2. (The entered value is
reflected with each other.)
Use case
At the time of cleaning
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the timing of cleaning as a guide: Select the item and
enter the timing of cleaning as a guide.
Caution
Clear the counter value after cleaning.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Related service mode
COPIER> COUNTER> CLN-SW> FD-U-2
COPIER> COUNTER> AVE-CLN> FD-U-2
8
Service Mode > COPIER > COUNTER > AVE-PRD1
T-8-95
8
Service Mode > COPIER > COUNTER > AVE-PRD1
■ AVE-PRD1
COPIER> COUNTER> AVE-PRD1
OZ-FIL1
PT cntr avg: Fixing ozone filter
Lv.1 Details
Display the average value of the fixing ozone filter on the parts
counter.
The average value on the left side is calculated based on the result
of parts replacement. The number of sheets transported at the timing
when the counter value is cleared by PRDC-1> OZ-FIL1 is used for
the result of parts replacement.
For the estimated life on the right side, enter the operator
replacement interval referring to the average value. It is linked to
PRDC-1> OZ-FIL1. (The entered value is reflected to each other.)
Use case
Improve the accuracy of replacement interval by judging the use
condition and environment based on the average value of the
counter and setting estimated life for each user.
Adj/set/operate method Select the item and enter the estimated life.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Related service mode
COPIER> COUNTER> PRDC-1> OZ-FIL1
OZ-FIL2
PT cntr avg: Primary charge ozone filter
Lv.1 Details
Display the average value of the primary charging ozone filter on the
parts counter.
The average value on the left side is calculated based on the result
of parts replacement. The number of sheets transported at the timing
when the counter value is cleared by PRDC-1> OZ-FIL2 is used for
the result of parts replacement.
For the estimated life on the right side, enter the operator
replacement interval referring to the average value. It is linked to
PRDC-1> OZ-FIL2. (The entered value is reflected to each other.)
Use case
Improve the accuracy of replacement interval by judging the use
condition and environment based on the average value of the
counter and setting estimated life for each user.
Adj/set/operate method Select the item and enter the estimated life.
Display/adj/set range
0 to 99999999
Unit
Number of sheets
Default value
0
Related service mode
COPIER> COUNTER> PRDC-1> OZ-FIL2
8-379