COPIER> ADJUST> CCD
MTF2-S7
MTF value setting 7: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S8
MTF value setting 8: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF2-S9
MTF value setting 9: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
100DF2GB
GB color drift crrctVL in img snsr[back]
Lv.2 Details
To correct the color drift between G-B lines in sub scanning direction
due to the back side scanner unit.
When the reader controller PCB is replaced or RAM is cleared, enter
the value of service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-256 to 256
Default value
0
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
COPIER> ADJUST> CCD
100DF2RG
RG color drift crrctVL in img snsr[back]
Lv.2 Details
To correct the color drift between R-G lines in sub scanning direction
due to the back side scanner unit.
When the reader controller PCB is replaced or RAM is cleared, enter
the value of service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-256 to 256
Default value
0
DFCH2R2
Complex chart No.2 data (R) [Front]
Lv.1 Details
To calculate the front/back linearity, set the front Red data of No.2
image in DADF complex chart.
Enter the value of reader's service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000
DFCH2R10
Complex chart No.10 data (R) [Front]
Lv.1 Details
To calculate the front/back linearity, set the front Red data of No.10
image in DADF complex chart.
Enter the value of reader's service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2550
Default value
0
DFCH2B2
Complex chart No.2 data (B) [Front]
Lv.1 Details
To calculate the front/back linearity, set the front Blue data of No.2
image in DADF complex chart.
Enter the value of reader's service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 2550
Default value
2000
DFCH2B10
Complex chart No.10 data (B) [Front]
Lv.1 Details
To calculate the front/back linearity, set the front Blue data of No.10
image in DADF complex chart.
Enter the value of reader's service label.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2550
Default value
0