COPIER > OPTION > IMG-MCON
C-SM-P-G
Setting of special paper gLUT (for PDL)
Lv.1 Details
To specify whether to use the special paper gLUT (for PDL).
CAL executes the control with using special paper gLUT. When there
is a failure in halftone on coated paper, use the linear control that is
the same control with quality paper group.
Use case
When there is a failure in halftone density or gradation on coated
paper.
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Linear control (same with quality paper group), 1: Use special
paper gLUT
Default value
1
Related service mode
COPIER> OPTION> IMG-MCON> C-SM-C-G
Supplement/memo
C-SM-P-G stands for "CAL_SpecialMedium_PDL_Gamma".
High-quality paper group: High-quality paper / recycled paper /
embossed paper / label / postcard / cotton
C-SM-C-G
Setting of special paper gLUT (for COPY)
Lv.1 Details
To specify whether to use the special paper gLUT (for COPY).
CAL executes the control with using special paper gLUT. When there
is a failure in halftone on coated paper, use the linear control that is
the same control with quality paper group.
Use case
When there is a failure in halftone density or gradation on coated
paper
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Linear control (same with quality paper group), 1: Use special
paper gLUT
Default value
1
Related service mode
COPIER> OPTION> IMG-MCON> C-SM-P-G
Supplement/memo
C-SM-C-G stands for "CAL_SpecialMedium_COPY_Gamma".
High-quality paper group: High-quality paper / recycled paper /
embossed paper / label / postcard / cotton
DH-TGT
Setting of D-half control target
Lv.1 Details
Setting of target data for D-half control.
When the reader is installed, D-half control sets the target by using
gradation data before the PASCAL control while using the detection
result of D-half control after PASCAL control. To execute control
using only the patch image scanning detection in the case of reader-
related failure, manually select the gradation data.
When the reader is not installed, selection is available for the
gradation data only.
Use case
In the case of reader-related failure
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 1
0: Detection result of D-half control immediately after PASCAL
control, 1: Gradation data
Default value
0
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-MCON
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-MCON
COPIER > OPTION > IMG-MCON
LOGLEVEL
Log acquisition level: For R&D
LOGCYCLE
Log acquisition interval: For R&D
8-262