■ IMG-LSR
COPIER > OPTION > IMG-LSR
S-SHD-01
Setting of jam judgment condition 1
Lv.1 Details
To set the number of continuous blank pages as a jam judgment
condition.
When the image whose video counter value is equal or lower than
"setting value of S-SHD-02 x 1000" continues for "setting value of
S-SHD-01" pages, it is judged as a jam and the jam code "0CFF" is
displayed.
Use case
When an image failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
- 32 to 32
-32 to -1: Not used
0: The number of blank pages is not used as a judgment condition
1, 2: Not used
3 to 32: Judged as a jam when blank paper continues for "setting
value" pages
Unit
Number of pages
Appropriate target value 6
Default value
0
Related service mode
COPIER> OPTION> IMG-LSR> S-SHD-02
S-SHD-02
Setting of jam judgment condition 2
Lv.1 Details
To set video counter value as a jam judgment condition.
When the image whose video counter value is equal or lower than
"setting value of S-SHD-02 x 1000" continues for "setting value of
S-SHD-01" pages, it is judged as a jam and the jam code "0CFF" is
displayed.
Use case
When an image failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
-32 to 32 (-32 to -1: Not used)
Appropriate target value 1
Default value
0
Related service mode
COPIER> OPTION> IMG-LSR> S-SHD-01
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-LSR
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > IMG-LSR
COPIER > OPTION > IMG-LSR
S-SHD-03
ON/OFF of charging voltage check
Lv.1 Details
To set whether to check OFF of charging voltage due to high voltage
leak.
When high voltage protection function works in the case of high
voltage leak, the jam code "0CFF" and the alarm code "300001" are
displayed.
When 1 is set, stop due to jam caused by high voltage does not
occur since OFF of charging voltage is not checked.
Use case
When an image failure occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
- 32 to 32
-32 to -1: Not used, 0: ON, 1: OFF, 2 to 32: Not used
Default value
0
S-SHD-04
[Not used]
S-SHD-05
[Not used]
S-SHD-06
[Not used]
S-SHD-07
[Not used]
S-SHD-08
[Not used]
S-SHD-09
[Not used]
S-SHD-10
[Not used]
S-SHD-11
[Not used]
S-SHD-12
[Not used]
S-SHD-13
[Not used]
S-SHD-14
[Not used]
S-SHD-15
[Not used]
S-SHD-16
[Not used]
S-SHD-17
[Not used]
S-SHD-18
[Not used]
S-SHD-19
[Not used]
S-SHD-20
[Not used]
S-SHD-SW
[Not used]
S-SHD-P
[Not used]
8-257
T-8-65
8-257