COPIER> FUNCTION> INSTALL
RGW-PORT
Set port number of sales co's server
Lv.1 Details
Set the port number of the sales company's server used by
Embedded-RDS.
Use case
At the time of using Embedded-RDS
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG, and
RGW-ADR as a set.
Display/adjust/set range 1 to 65535
Default value
443
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, COM-TEST, COM-LOG,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
COM-TEST
Disply connect result w/ sales co server
Lv.1 Details
Display the result of the test of connection with the sales company's
server.
Use case
At the time of using Embedded-RDS
Adj/set/operate method Select the item and press the OK key.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG, and
RGW-ADR as a set.
Display/adjust/set range During operation: ACTIVE, When connection is completed: OK,
When connection failed: NG
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-LOG,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
COM-LOG
Disply connect error w/ sales co server
Lv.1 Details
Display error information when the connection with the sales
company's server failed.
Use case
At the time of using Embedded-RDS
Adj/set/operate method Display only
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG, and
RGW-ADR as a set.
Display/adjust/set range Year, date, time, error code, error detail information (maximum 128
characters)
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > INSTALL
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > INSTALL
COPIER> FUNCTION> INSTALL
RGW-ADR
RL setting of sales company server
Lv.1 Details
Set the URL of the sales company's server used by Embedded-RDS.
Use case
At the time of using Embedded-RDS
Adj/set/operate method 1) Select the URL.
2) Enter the URL and press the OK key.
3) Turn OFF/ON the main power.
Caution
• Do not use Shift-JIS character strings.
• Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG, and
RGW-ADR as a set.
Display/adjust/set range URL
Default value
https://a01.ugwdevice.net/ugw/agentif010
Related service mode
COPIER> FUNCTION> INSTALL> E-RDS, RGW-PORT, COM-TEST,
COM-LOG
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
CNT-DATE
Set counter send start date to SC server
Lv.1 Details
Set the year, month, date, hour, and minute to send counter
information to the sales company's server.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
When the Embedded-RDS third-party expanded function is available
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Display/adjust/set range YYYYMMDDHHMM (12 digits)
YYYY: Year, MM: Month, DD: Date, HH: Hour, MM: Minute
Default value
000000000000
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol
CNT-INTV
Set counter send interval to SC server
Lv.1 Details
Set the interval of sending counter information to the sales
company's server in a unit of one hour.
This is displayed only when the Embedded-RDS third-party extended
function is available.
Use case
When the Embedded-RDS third-party expanded function is available
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Display/adjust/set range 1 to 168(= 1 week)
Unit
1 hour
Default value
24
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol