COPIER> ADJUST> FEED-ADJ
REG-R
Adj of right edge regist position
Lv.1 Details
Based on the value read by a test print, adjust the laser writing start
position in main scanning direction that is set at the factory.
Set the value in which the right edge margin is within the standard (2.5
-/+ 0.5 mm).
Enter the value for front into 1st line and for back into 2nd line
respectively.
As the value is changed by 1, the image is shifted by 0.1 mm toward
the horizontal scanning direction.
+: toward rear (right edge margin is decreased)
-: toward front(right edge margin is increased)
Use case
• At the initial installation check.
• At the check/adjustment when the CIS sensor in active registration
is replaced.
• At the check/adjustment when the active registration unit is
replaced.
Adj/set/operate method 1) Output a test print.
2) Measure the right edge margin.
3) Enter the adjustment amount for margin.
4) Output a test print and check it.
Caution
This setting is applied to all the media settings that users are set.
Execute the adjustment on media basis in additional function mode.
Display/adjust/set range -50 to 50
Unit
0.1 mm
Default value
0
SFT-OHP
Adj of OHP right edge regist position
Lv.1 Details
Based on the value read by a test print, adjust the laser writing start
position of transparency in main scanning direction that is set at the
factory.
Set the value in which the right edge margin is within the standard (2.5
-/+ 0.5 mm).
As the value is changed by 1, the image is shifted by 0.1 mm toward
the main scanning direction.
+: toward rear (right edge margin is decreased)
-: toward front(right edge margin is increased)
Use case
• At the initial installation check.
• At the check/adjustment when the scanner unit is replaced.
• At the check/adjustment when the active registration unit is
replaced.
• On the adjustment request by users.
Adj/set/operate method 1) Output a test print.
2) Measure the right edge margin.
3) Enter the shift amount from the current.
4) Output a test print and check it.
Caution
This setting is applied to all the media settings that users are set.
Execute the adjustment on media basis in additional function mode.
Display/adjust/set range -50 to 50
Unit
0.1 mm
Default value
0
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > FEED-ADJ
COPIER> ADJUST> FEED-ADJ
OHT-SKEW
Adj of OHP skew amount
Lv.1 Details
Based on the value read by a test print, adjust the skew offset
amount of transparency that is set at the factory.
As the value is changed by 1, it rotates by 0.01 mm per 152 mm in
longitudinal direction.
+: clockwise (trailing edge right edge margin is decreased)
-: counterclockwise (trailing edge right edge margin is increased)
Use case
• At the initial installation check.
• At the check/adjustment when sensors related to the active
registration skew are replaced.
• At the check/adjustment when the active registration unit is
replaced.
• On the adjustment request from users.
Adj/set/operate method 1) Output a test print.
2) Measure skew degree.
3) Enter the skew adjustment amount.
4) Output a test print and check it.
Caution
This setting is applied to all the media settings that users are set.
Execute the adjustment on media basis in additional function mode.
Display/adjust/set range -500 to 500
Unit
0.01 mm
Default value
0
Supplement/memo
Entry value = skew amount in longitudinal direction (mm) /
longitudinal dimension (mm) * 15200
REG-CST
Storage side regst adj dspl:Pikup deck1
Lv.1 Details
Display the side registration misalignment position amount of the
storage of the host machine deck.
As an indicator when side registration of the storage is adjusted.
Use case
When adjusting the side registration of the storage in case that the
correction is not enough at the active registration.
Adj/set/operate method 1) Report the side registration correction amount of each pickup
cassette at the last feed.
2) Display the 1) value on the control panel (rear: +, front: -, unit:
mm)
3) Adjust the side registration position of pickup cassette according
to the displayed value.
If the value is within the adjustment range of active registration (-1
to 1 mm), adjustment is not necessary.
Caution
• After the side registration adjustment of storage, feed the paper
and check the result.
• Do not move the storage that is adjusted for transparency other
than user's request.
Display/adjust/set range -10 to 10
Unit
1 mm
Appropriate target value -6 to 6
Default value
0
Supplement/memo
On [side registration shift amount offset] that is the fixing assembly
paper edge measure, the value is displayed regardless of the side
registration correction amount.