Canon imagePRESS 1135 Series Service Manual page 1317

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> COUNTER> PD1-SW
FILTER
Switch dspl: Filter counter
Lv.1 Details
Set whether or not to display the following filters in the list of parts to
be replaced under the operator maintenance mode.
• 2 fixing ozone filters
• Primary charging ozone filter
• 2 fixing toner filters
• Primary charging toner filter
• Developing toner filter
When it is selected to display the filters and the counter value
reached the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> PRDC-1> OZ-FIL1, OZ-FIL2, TN-FIL1, TN-
FIL2, TN-FIL3
PRM-U-A
Switch dspl: Primary charging assy countr
Lv.1 Details
Set whether or not to display the primary charging assembly in the
list of parts to be replaced under the operator maintenance mode.
When it is selected to display the unit and the counter value reached
the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> DRBL-1> PRM-UNIT
PRE-W-U
Switch dspl: Pre-pri trns chrg assy cuntr
Lv.1 Details
Set whether or not to display the pre-primary transfer charging
assembly in the list of parts to be replaced under the operator
maintenance mode.
When it is selected to display the unit and the counter value reached
the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> DRBL-1> PO-UNIT
8
Service Mode > COPIER > COUNTER > DB1-SW
T-8-93
8
Service Mode > COPIER > COUNTER > DB1-SW
■ DB1-SW
COPIER> COUNTER> DB1-SW
2TR-ROLA
Switch dspl: Sec trns ex-roller prts cntr
Lv.1 Details
Set whether or not to display the secondary transfer external roller
in the list of parts to be replaced under the operator maintenance
mode.
When it is selected to display the unit and the counter value reached
the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> DRBL-1> 2TR-ROLL
FX12UP-A
Switch dspl: Fixing roller parts counter
Lv.1 Details
Set whether or not to display the fixing roller in the list of parts to be
replaced under the operator maintenance mode.
When it is selected to display the unit and the counter value reached
the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> DRBL-1> FX-UP-RL
FX-WEB-A
Switch dspl: Fixing web parts counter
Lv.1 Details
Set whether or not to display the fixing web in the list of parts to be
replaced under the operator maintenance mode.
When it is selected to display the unit and the counter value reached
the specified value, it is also displayed in the caution list.
Use case
To set whether or not to display the unit in the replacement parts list
under the operator maintenance mode
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 1
0: Hide, 1: Display
Default value
Subject to the destination
Related service mode
COPIER> COUNTER> DRBL-1> FX-WEB
8-374
8-374

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents