Canon imagePRESS 1135 Series Service Manual page 1114

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> ADJUST> CCD
MTF2-S12
MTF value setting 12: sub scan [Front]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 20 to 85
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M10
MTF value setting 10: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-M11
MTF value setting 11: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
8
Service Mode > COPIER > ADJUST (Adjustment Mode) > CCD
COPIER> ADJUST> CCD
MTF-M12
MTF value setting 12: main scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S10
MTF value setting 10: sub scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
MTF-S11
MTF value setting 11: sub scan [Back]
Lv.1 Details
Setting value for MTF filter coefficient calculation.
Input the value in the service label of the reader.
Use case
When the reader controller PCB is replaced or RAM is cleared.
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power switch.
Caution
After the setting, execute COPIER> FUNCTION> CCD> MTF-CLC.
Display/adj/set range
20 to 85
Unit
0.01
Appropriate target value 40 to 70
Default value
50
Related service mode
COPIER> FUNCTION> CCD> MTF-CLC
8-171
8-171

Hide quick links:

Advertisement

Table of Contents
loading