Canon imagePRESS 1135 Series Service Manual page 1169

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER> FUNCTION> MISC-P
ITB-EDGE
Creation of ITB edge profile
Lv.1 Details
Measure the ITB edge and create the edge profile.
Use case
• To create the initial profile for ITB displacement control at the time
of replacement of ITB
• To correct ITB alignment after disengagement/engagement of the
ITB positioning plate
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range During operation: ACTIVE, When operation finished normally: OK,
When operation failed: NG
Required time
Approx. 1 minute
Related user mode
Operator maintenance mode>Adjustment/Cleaning>Initial setting
after replacement of ITB
WTNR-ALL
Delivery of all waste toner
Lv.1 Details
Deliver the waste toner in the machine to the waste toner container.
Operation continues for 1 minute.
Use case
• At the time of replacement of the waste toner container
• When waste toner clog occurred (Cleaner unit -- Waste buffer --
Waste toner container)
• When moving the device
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range During operation: ACTIVE, At termination: OK
Required time
1 minute
1-ROT-EX
Idling at primary transfer current apply
Lv.2 Details
Perform idling while applying a bias to the primary transfer roller.
When the value is incremented by 1, idling time is increased by 10
seconds.
Use case
To adjust a resistance value for the primary transfer roller when an
image failure occurs
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range 0 to 30
Unit
10 seconds
Supplement/memo
The ITB and photosensitive drum are also driven.
The operation stops automatically or by pressing the STOP key.
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > MISC-P
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > MISC-P
COPIER> FUNCTION> MISC-P
2-ROT-EX
Idling at secndry transfer current apply
Lv.2 Details
Perform idling while applying a reverse bias to the secondary transfer
inner roller.
When homopolar current continues to be applied to the secondary
transfer inner roller, the resistance increases. Because the voltage
increases, the life of the roller is shortened when the machine has
been reaching the end of life, causing an image failure to occur due
to electric discharge.
When a reverse bias is applied to the secondary transfer inner roller
during idling, the resistance decreases and the life of the roller can
be prolonged.
At the time of execution, the reverse bias specified by 2TR-LIFE is
applied.
When the value is incremented by 1, idling time is increased by 10
seconds.
The operation automatically stops or is stopped by the Stop key after
execution.
Use case
To prolong the life of the secondary transfer roller when an image
failure occurs as the roller has been reaching the end of life
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range 0 to 30
Unit
10 seconds
Supplement/memo
The ITB and photosensitive drum also operate while the secondary
transfer external roller is engaged.
The operation stops automatically or by pressing the STOP key.
WB
Reverse toner forcible eject(white band)
Lv.2 Details
Forcibly spit the reverse toner.
The operation automatically stops after execution.
Use case
When operating the machine in high-duty and low-humidity
environment for a long period of time (implemented by the
administrator)
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range During operation: ACTIVE, When operation finished normally: OK,
When operation failed: NG
Required time
60 seconds
BB
Toner forcible eject (black band)
Lv.2 Details
Forcibly discharge low-charge toner, and send it to the drum cleaner
unit.
The operation automatically stops after execution.
Use case
When operating the machine in low-duty and high-humidity
environment for a long period of time (implemented by the
administrator)
Adj/set/operate method Select the item and press the OK key.
Display/adjust/set range During operation: ACTIVE, When operation finished normally: OK,
When operation failed: NG
Required time
60 seconds
8-226
8-226