Canon imagePRESS 1135 Series Service Manual page 1228

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER > OPTION > USER
MB-CCV
Control card usage limit for mail box
Lv.2 Details
Restricting use of control card in the mail box
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Unlimited (no restriction), 1: Limitation (restriction) apply
Default value
0
CONTROL
Charge setting of PDL job
Lv.1 Details
Setting of charging count transmission of PDL job to the connecting
charging management device (coin manager or non-Canon-made
control card).
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: No charge, 1: Charge
Default value
0
B4-L-CNT
Count setting of B4 size
Lv.1 Details
Setting of B4 count with software counter 1 to 8 as to whether B4 is
counted as large size or small size.
Selecting 1 counts B4 or larger size paper as large size while paper
less than B4 size as small size.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Small size, 1: Large size
Default value
0
Related service mode
COPIER> OPTION> FNC-SW> SC-L-CNT
TRY-STP
Stop setting at finisher tray full
Lv.2 Details
Setting to stop/continue output at the time of tray full detection of the
finisher
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: At the time of tray full detection, 1: Height detection only
Default value
0
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
COPIER > OPTION > USER
MF-LG-ST
Dspl/hide of extra long original button
Lv.2 Details
Setting to display/hide [Extra-Length Original] button.
Use case
When making copy using the extra-length original from DADF.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Hide (no display), 1: Display
Default value
0
Supplement/memo
Up to 630 mm length paper is supported when using DADF (option).
CNT-DISP
Dspl/hide of serial No.
Lv.2 Details
Setting to display/hide serial No. on counter-check screen.
Use case
Setting to display/hide serial No. on the screen to check counter
status
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Display, 1: Hide (no display)
Default value
0
PH-D-SEL
Set of dither matrix in screen proces
Lv.2 Details
In case of copy output, B&W BOX scan output or B&W SEND output,
to set the screen dither matrix that is used in image half-toning
processing.
If moiré occurs frequently, set "0: 134 line".
When the setting is changed, PG screen ruling output in PASCAL
control is also changed.
Use case
In case of copy output, B&W BOX scan output or B&W SEND
output, when moiré occurs frequently. Especially, moiré occurs in the
halftone density part of gradation area on photos and images.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Caution
• This mode is available only when making copy
• Do not use this mode at normal servicing
Display/adj/set range
0 to 1
0: 134-line, 1: 141-line
Default value
1
COPY-JOB
Setting of copy job reservation
Lv.1 Details
Setting to enable/disable copy job reservation when the card reader/
coin manager is used.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Enable (available), 1: Disable (not available)
Default value
0
8-285
8-285

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents