Canon imagePRESS 1135 Series Service Manual page 1247

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER > OPTION > USER
DK13ASST
Air heater set of M-inserter lower deck
Lv.1 Details
Setting the condition (media, environment) to turn ON the floatation
air heater in the lower deck of the multi insertion unit.
When switching media from non-coated paper to coated paper,
pickup is not be started until the floatation air heater reaches the
specified temperature. To shorten wait time, specify the setting that
is not dependent on media.
If the use environment is close to the threshold for turning ON/OFF,
wait time gets longer because of frequent switch. To shorten wait
time, specify the mode always to be ON.
Use case
Upon request to shorten the wait time.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Caution
• In the case to specify the mode that is not dependent on media, be
sure to inform the user about the possibility of drop in transferring
performance of non-coated paper and get an approval of the user
before executing this mode.
• In the case to always turn ON, be sure to inform the user about the
possibility of drop in transferring performance under low humidity
environment and get an approval of the user before executing this
mode.
Display/adj/set range
0 to 2
0: Dependent on media and environment condition
1: Dependent on environment condition (no dependence on media)
2: Always turning ON the air heater (no dependence on environment
and media)
Default value
0
Related service mode
COPIER> OPTION> USER> DK11ASST, DK12ASST
DK10BSTP
Float fan stop set in POD3 low deck oprn
Lv.1 Details
Turning OFF the floatation fan if there is no request for image
formation even the timing for image formation request is over while
the lower deck of the 2nd (additional) secondary POD deck is
continuously in operation.
Specify how many second to turn OFF the fan after the timing for
image formation request.
Use case
To change the setting value in the case to change the time for turning
OFF of the floatation fan during continuous operation.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 20
Unit
1 second
Default value
20
Related service mode
COPIER> OPTION> USER> DK1-BSTP to DK9-BSTP
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
COPIER > OPTION > USER
INS-ACC
ON/OFF of multi inserter ACC
Lv.1 Details
Set ON/OFF of the automatic cassette change (ACC) function in the
multi-inserter.
Use case
To perform automatic cassette change in the multi-inserter.
Adj/set/operate method Enter the setting value and press the OK key.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Related service mode
COPIER> OPTION> DSPLY-SW> DK11REST, DK12REST,
DK13REST
Related user mode
Initial setting/registration> Common specification settings> ON/OFF
of automatic cassette selection
DK11BSTP
Float fan stop in M-insrtr upr deck oprn
Lv.1 Details
Turn off the paper separation fan when an image formation request
was not made even after the timing of the request has elapsed
during continuous operation of the multi-inserter upper deck. Make
a setting of "after how many seconds the fan is turned off when the
timing of the request has elapsed".
Use case
Change the setting value to change the time until turning off the
paper separation fan which has been operating continuously.
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 20
Unit
1 second
Default value
20
Related service mode
COPIER> OPTION> USER> DK12BSTP, DK13BSTP
DK12BSTP
Float fan stop in M-insrtr mid deck oprn
Lv.1 Details
Turn off the paper separation fan when an image formation request
was not made even after the timing of the request has elapsed
during continuous operation of the multi-inserter middle deck. Make
a setting of "after how many seconds the fan is turned off when the
timing of the request has elapsed".
Use case
Change the setting value to change the time until turning off the
paper separation fan which has been operating continuously.
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 20
Unit
1 second
Default value
20
Related service mode
COPIER> OPTION> USER> DK11BSTP, DK13BSTP
8-304
8-304

Hide quick links:

Advertisement

Table of Contents
loading