Mgmt Vlan - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
base bridge-mode {dot1d-bridge|dot1q-vlan}
The parameters have the following meaning:
Parameter
dot1d-bridge
dot1q-vlan
Result
The device mode is configured.
Further notes
You display the status of this function and other information with the show vlan device
info command.
7.2.2.6

mgmt vlan

Description
With this command, you change the agent VLAN ID. You can only use VLANs that have already
been configured.
Note
Changing the agent VLAN ID
If the configuration PC is connected directly to the device via Ethernet and you change the
agent VLAN ID, the device is no longer reachable via Ethernet following the change.
Requirement
● In "base bridge-mode", the mode for the device is set to dot1q-vlan
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
mgmt vlan <vlan-id(1-4094)>
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Sets the mode of the device to "transparent" for
the Spanning Tree protocol.
sets the mode of the device to "VLAN-aware"
for a virtual bridged LAN.
Network structures
7.2 VLAN
Range of values / note
Default setting
-
289

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents