11.3.5.10

vap communication with other-vaps (access point)

Description
With this command, you specify that clients logged on to different SSIDs of an access point
can communicate with each other.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
vap communication with other-vaps
Result
The communication option via different SSIDs of an access point is enabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You disable the function with the no vap communication with other-vaps command.