Security and authentication
11.3 WLAN
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call up the command with the following parameters:
no vap inter-ap-blocking allowed address {ipv4 <ipv4-address>}
The parameters have the following meaning:
Parameter
ipv4
ipv4-
address
Result
The entry was deleted from the list.
11.3.5.16

vap inter-ap-blocking

Description
This command restricts the communication of the clients. Clients can only access SCALANCE
W700 devices whose IP address was configured on the access point with the command vap
inter-ap-blocking allowed address.
Note
The command is only available when the following requirements are met:
● Access point mode
● The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
540
Description
Keyword for an IPv4 ad‐
dress
IP address
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
-
Enter a valid IPv4 address.