Snmp Access - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

The parameters have the following meaning:
Parameter
v3only
all
Result
The setting is configured.
8.6.2.4

snmp access

Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName> {v1|v2c|v3 {auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|
none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
GroupName
Version
Authentication
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Only SNMPv3 queries are processed
All SNMP queries are processed
Description
Name of the group to which access is
configured
Selects the version of the protocol used ● v1
Selects the authentication method.
Network protocols
8.6 SNMP
Range of values / note
-
Default: all
Range of values / note
max. 32 characters
● v2c
● v3
● auth
Enables MD5 or SHA as
authentication method
● noauth
No authentication
● priv
Enables authentication and
encryption
415