12.1 Diagnostics
Parameter
email
trap
faults
all
Result
The setting deciding which message of the device is stored or forwarded is configured.
Further notes
You display the status of the events and the clients with the show events config command.
You delete the settings with the no event config command.
With this command, the clients are not enabled.
To enable the clients, use the client config command.
Note
Changing several message types or clients
With each command call, you can only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first select
the all option and then disable individual elements.
12.1.6.5

no event config

Description
With this command, you configure which of the various message types of the device will no
longer be stored or forwarded.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no event config {cold-warmstart | linkchange | authentication-
failure | power-change | faultstate-change | stp-change | overlap-ap
594
Description
Client that sends the e-mails
Client that sends the SNMP traps
The device triggers an error. The error LED lights up.
All clients at once
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08