wlan signal-recorder display (client)

Description
With this command, you configure and start recording with the signal recorder without
specifying a total for the measured values. The measured values are output in the CLI and
logged in files. The files can be downloaded as a zip file using http or tftp. The values are
stored every 10 minutes and overwrite the existing values. The file therefore contains the
values the last time they were stored.
Note
This command is only available in the client mode.
Requirement
● The WLAN interface is enabled.
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call up the command with the following parameters:
wlan signal-recorder <wlan 0/X> <ms (100 - 60000)> [bidirectional]
display
The parameter has the following meaning:
Parameter
wlan 0/X
ms
bidirectional
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 29)".
120
Description
WLAN interface
The interval in milliseconds (ms) be‐
tween acquisition of two measured val‐
ues
The values of the access point are re‐
corded.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
Enter a valid interface.
100 - 60000
The first measured value is dis‐
played only after the set time interval
has elapsed.
Requirement
Firmware version > 6.1 is installed
on the access point.
Note
The access point sends its data to a
maximum of 3 clients on which sig‐
nal recorders are running. The ac‐
cess point data is not displayed on
other clients.
Configuration Manual, 09/2017, C79000-G8976-C324-08