No Spanning-Tree Compatibility - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.3 Spanning Tree
Result
The compatibility version of the protocol is selected.
Further notes
You can reset the setting to the default mst with the no spanning-tree
compatibility command.
You can display the status of this function and other information with the show spanning
tree detail command.
You can display information about active ports with the show spanning tree active
command.
7.3.3.4

no spanning-tree compatibility

Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the spanning-tree compatibility command.
You can display the status of this function and other information with the show spanning
tree detail command.
312
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents