Configuration
4.3 Reset and Defaults
Select one of the following configuration settings:
● Device restart with the current configuration
● Device restart with the factory configuration settings with the exception of the following
parameters:
– IP addresses
– Subnet mask
– IP address of the default gateway
– DHCP client ID
– DHCP
– System name
– System location
– System contact
– User names and passwords
– Mode of the device
● Device restart with the factory configuration settings.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart[{memory|factory}]
The parameters have the following meaning:
● if no parameters are specified: restarts the system with the current configuration
Parameter
memory
factory
100
Description
Restores the factory settings of the device and restarts the device. The parameters
listed above are unaffected by a reset.
Restores the factory settings of the device and restarts the device.
The default factory settings depend on the device.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08