Security and authentication
11.6 Management Access Control List
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no authorized-manager ip-source <ip-address>
The parameters have the following meaning:
Parameter
ip-address
subnet-mask
prefix-length
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 29)".
Result
An authorized manager is deleted from the list.
Further notes
You configure the interfaces and protocols via which an authorized manager is allowed to
access the device with the authorized-manager ip-source command.
You show the information about the configuration of the authorized managers with the show
authorized-manager command.
580
[{<subnet-mask>|/<prefix-length(0-32)>}]
Description
Specifies the network or the IP address
for which the IP manager is authorized
Subnet mask that restricts the authori‐
zation
Decimal representation of the mask as
a number of "1" bits
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Range of values / note
Enter a valid IP address or a net‐
work
Enter a valid mask
0 ... 32