8.6 SNMP
If optional parameters are not specified when configuring, the default values apply.
Result
The SNMP target parameters are configured.
Further notes
You delete the SNMP target parameters with the no snmp targetparams command.
You display settings of this function with the show snmp targetparam command.
You configure the user profile with the snmp user command.
You display the list of users with the show snmp user command.
8.6.2.19

no snmp targetparams

Description
With this command, you delete the SNMP target parameters.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp targetparams <ParamName>
The parameter has the following meaning:
Parameter
ParamName
Result
The SNMP target parameters are deleted.
Further notes
You change the SNMP target parameters with the snmp targetparams command.
You display settings of this function with the show targetparam command.
430
Description
Name of the SNMP parameter
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
max. 32 characters
Configuration Manual, 09/2017, C79000-G8976-C324-08