The destination address is configured.
Note
Destination address not in the agent IPv4 subnet
If the destination address is not in the agent IPv4 subnet, a gateway must be entered.
The Base Bridge mode "802.1Q VLAN Bridge"
If you have configured the "Base Bridge Mode" "802.1Q VLAN Bridge", pings are sent into the
management VLAN.
Further notes
You display this setting and other information with the show wlan force roaming ip-
down command.
You assign an the destination address to a VAP interface with the port command.
7.1.8.3

lost (Access Point)

Description
With this command you specify the maximum number of consecutive lost ping responses.
When this number is reached for a destination address, this destination address counts as
being unreachable (down).
Note
This command is available only in access point mode.
Requirement
You are in the force roaming configuration mode.
The command prompt is as follows:
cli (config-wlan-froid-$)#
Syntax
Call up the command with the following parameters:
lost <lost (1-5)>
The parameter has the following meaning:
Parameter
lost
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Number of ping responses
Network structures
7.1 WLAN
Range of values / note
1 - 5