Network structures

7.2 VLAN

7.1.8.6

no port (Access Point)

Description
With this command, you disable the monitoring of the VAP interface.
Note
This command is available only in access point mode.
Requirement
You are in the force roaming configuration mode.
The command prompt is as follows:
cli (config-wlan-froid-$)#
Syntax
Call up the command with the following parameters:
no port <vapX 0/Y>
The parameter has the following meaning:
Parameter
vapX 0/Y
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 29)".
Result
The function is disabled.
Further notes
You display this setting and other information with the show wlan force roaming ip-
down command.
You enable this setting with the port command.
7.2
VLAN
This section describes commands for configuring and managing virtual networks (VLANs).
278
Description
VAP interface
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
Specify a valid interface.
Configuration Manual, 09/2017, C79000-G8976-C324-08