No Wlan Data Rates-11N Selected Only (Access Point) - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.1 WLAN
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
● The transmission standard IEEE 802.11n or IEEE 802.11n only is set.
Syntax
Call the command without parameter assignment:
wlan data rates-11n selected only
Result
The function is enabled.
Further notes
You display the setting with the show wlan data rates command.
You disable the function with the no wlan data rates-11n selected only command.
You configure the data transmission speeds with the wlan data rate-11n command.
You configure the transmission standard with the wlan mode command.
7.1.5.30

no wlan data rates-11n selected only (access point)

Description
With this command, you enable / disable the automatic selection of the data transmission
speed.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
● The transmission standard IEEE 802.11n or IEEE 802.11n only is set.
234
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08