cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc protocol-support {pnio | ethernet-ip}
Parameter
pnio
ethernet-ip
Result
The optimized support of PROFINET or Ethernet/IP is enabled.
Further notes
You display the setting with the show wlan ipcf-mc command.
5.6.2.4

wlan ipcf-mc cycle-time (access point)

Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
● iPCF-MC is enabled with the aid of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5 907-8PA00)
– W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you configure the cycle time for iPCF-MC.
Requirement
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Keyword for the PROFI‐
NET
Keyword for the Ether‐
Net/IP
Functions specific to SCALANCE
Range of values / note
5.6 iPCF-MC
143