Syntax
Call the command without parameters:
vap inter-ap-blocking
Result
The client can only communicate via the Ethernet interface with SCALANCE W700 devices
that were configured as permitted communications partners.
Further notes
The show wlan inter-ap-blocking allowed addresses vapX 0/Y command
shows information about the SCALANCE W700 devices with which communication is possible.
With the vap inter-ap-blocking allowed address command, you configure a
SCALANCE W700 device as a permitted communications partner.
11.3.5.17

no vap inter-ap-blocking

Description
This command allows unrestricted communication from a client to all SCALANCE W700
devices that can be reached via the access point.
Note
The command is only available when the following requirements are met:
● Access point mode
● The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameters:
no vap inter-ap-blocking
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Security and authentication
11.3 WLAN