Network protocols
8.6 SNMP
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp notify <NotifyName>
The parameter has the following meaning:
Parameter
NotifyName
Result
The details of the SNMP notifications are deleted.
Further notes
You change the details of an SNMP group with the snmp notify command.
You display the configured SNMP notifications with the show snmp notif command.
You display the configured SNMP target addresses with the show snmp targetaddr
command.
8.6.2.16

snmp targetaddr

Description
With this command, you configure the SNMP target address.
Requirement
● The SNMP target parameters are configured.
● You are in the Global configuration mode.
The command prompt is:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp targetaddr <TargetAddressName> param <ParamName>
426
Description
Name of the notification
{ipv4 <IPAddress> | fqdn-name <FQDN> | ipv6 <IP6-Address> }
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Range of values / note
max. 32 characters