System time
6.2 NTP client
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call the command without parameter assignment:
no ntp server
Result
The connection to a server is deleted on the NTP client.
Further notes
You configure the connection to a server with the ntp server command.
See also
Interface identifiers and addresses (Page 29)
6.2.3.3

ntp time diff

Description
With this command, you configure the time difference between the device and the NTP server.
Requirement
You are in the NTP configuration mode.
The command prompt is as follows:
cli(config-ntp)#
Syntax
Call up the command with the following parameters:
ntp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+
-
176
Description
Time zones to the west of the NTP server time zone
Time zones to the east of the NTP server time zone
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface