Add Log; Client Config - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Diagnostics
12.1 Diagnostics
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
● If you exit the EVENTS configuration mode with the exit command, you return to the
Global configuration mode.
● If you exit the EVENTS configuration mode with the end command, you return to the
Privileged EXEC mode.
12.1.6.1

add log

Description
With this command, you create an entry in the log.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
add log <log-entry>
The parameter has the following meaning:
Parameter
log-entry
Result
The entry has been made in the logbook.
12.1.6.2

client config

Description
With this command, you enable one of the clients that processes or forwards the messages
of the device.
The following clients are available:
● syslog: sends the messages to the Syslog server
● trap: sends the messages as SNMP trap to a configured recipient
● email: sends the messages as e-mail
590
Description
Entry in the logbook
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
max. 150 characters
Configuration Manual, 09/2017, C79000-G8976-C324-08