interval (Access Point)

Description
With this command, you specify the interval at which echo messages (pings) are sent.
Note
This command is available only in access point mode.
Requirement
You are in the force roaming configuration mode.
The command prompt is as follows:
cli (config-wlan-froid-$)#
Syntax
Call up the command with the following parameters:
interval <interval (100-5000)>
The parameter has the following meaning:
Parameter
interval
Result
The setting is configured.
Further notes
You display this setting and other information with the show wlan force roaming ip-
down command.
276
Description
Interval
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
Enter the required interval.
100 .. 5000 seconds