Permit Icmp - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Parameter
src-ip-address
src-ip-address
mask
any
host
dest-ip-addres
dest-ip-addres
mask
dscp
value
value
For information on names of addresses and interfaces, refer to the section "Interface identifiers
and addresses (Page 29)".
Result
The IP access list has been configured.
Note
Subnet mask for individual hosts
If you create the rule for a single system (one IPv4 address), specify the subnet mask
"255.255.255.255". As an alternative, you can specify the keyword "host" followed by the IPv4
address.
Further notes
You delete an IP access control list with the no ip access-list standard <acl-
num> command.
You display the configuration of the access control list with the show access-lists
command.
11.5.5.3

permit icmp

Description
With this command, you configure an IP access control list for ICMP frames.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Source IP address
Network source address
Corresponding subnet mask
Blocks all outgoing frames
Keyword for a an individual IPv4 ad‐
dress
Destination IPv4 address
Network destination address
Corresponding subnet mask
Value
Keyword for the Differentiated Services
Codepoint
Value for the Differentiated Services Co‐
depoint
Security and authentication
11.5 IP access control list
Range of values / note
Enter a valid IP address.
Enter a valid combination of IPv4
address and subnet mask.
-
-
Enter a valid IPv4 address.
Enter a valid combination of IPv4
address and subnet mask.
0 ... 63
-
0 ... 63
565

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents