Configuration
4.1 System
Further notes
You enable automatic logout with the cli-console-timeout command.
You display the current timeout setting with the show cli-console-timeout command.
4.1.10.9

pnio

Description
With this command, you configure the setting for PROFINET after the next restart of the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
pnio {off|on}
The parameters have the following meaning:
Parameter
off
on
Result
PROFINET is enabled or disabled after the next restart.
Further notes
You display the current PROFINET configuration with the show pnio command.
You restore the default settings of the PROFINET profile with the restart command.
72
Description
PROFINET is disabled.
PROFINET is activated.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
If a PROFINET connection is established; in
other words the PROFINET AR status is "On‐
line", you cannot disable PROFINET.
When PROFINET is turned on, EtherNet/IP is
turned off. The switchover from PROFINET
and EtherNet/IP has no effect on DCP.