12.1.6.12

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog | authlog } { info | warning |
critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
authlog
info
warning
critical
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the no severity command.
You display the status of this function and other information show events severity
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
System event messages are sent by e-
mail.
System event messages are entered in
the log table.
System event messages are entered in
the syslog file.
System event messages are entered in
the log table for authentications.
System events are processed as of the
severity level "Information".
System events are processed as of the
severity level "Warning".
System events are processed as of the
severity level "Critical".