Vap Inter-Ap-Blocking Allowed Address - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Security and authentication
11.3 WLAN
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with ethernet
Result
The communication option is disabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the vap communication with ethernet command.
See also
vap communication with ethernet (access point) (Page 537)
11.3.5.14

vap inter-ap-blocking allowed address

Description
With this command you specify which SCALANCE W700 devices are accessible to the clients.
Note
The command is only available when the following requirements are met:
● Access point mode
● The SCALANCE W700 device is equipped with one of the following KEY-PLUGs:
– W780 iFeatures (MLFB 6GK5907-8PA00)
– W700 Security (MLFB 6GK5907-0PA00)
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
538
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents