Mac Access-List Extended - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
11.4.2.1

mac access-list extended

Description
With this command, you generate a MAC access control list and change to the MAC ACL
configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
mac access-list extended<access-list-number(1-20)>
The parameter has the following meaning:
Parameter
access-list-
number
Result
A MAC access control list has been generated.
You are now in the MAC ACL configuration mode.
The command prompt is as follows:
cli(config-ext-macl)#
Further notes
You delete the MAC access control list with the no mac access-list extended command.
You exit the MAC ACL configuration mode with the exit command.
You display the configuration of the access control list with the show access-lists
command.
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Number of the access control list
Security and authentication
11.4 MAC access control list
Range of values / note
1 ... 20
547

Hide quick links:

Advertisement

Table of Contents
loading