No Spanning-Tree - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Network structures
7.3 Spanning Tree
Further notes
You can reset the setting to the default with the no spanning-tree (properties) command.
You display these settings and other information with the commands that start with show
spanning tree ....
7.3.4.2

no spanning-tree

Description
With this command, you reset the various properties of the spanning tree function to the default
value:
The default values are as follows:
Parameter
cost
disable
link-type
portfast
port-priority
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no spanning-tree {cost|disable|link-type|portfast|port-priority}
The parameters have the following meaning:
Parameter
cost
disable
link-type
portfast
port-priority
326
Default value
if dynamic calculation of the path costs is not enabled:
● 200000 for physical interfaces
● 199999 for port channels
The spanning tree function is enabled on the interface
● point-to-point
The connection is configured as full-duplex
● shared
in all other cases
disabled
128
Description
Keyword for the costs of the port for calculating the lowest-cost path.
Enables the interface for spanning tree.
Connection status of the following network segment
Disables the PortFast function.
Keyword for the priority of the interface
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface